    The AIRINS Sniffer4D Nano 2 Plus Multi-Gas turns a drone into a mobile air-quality monitoring system, measuring multiple gases and particulate matter simultaneously. It provides real-time, high-resolution gas concentration data that can be mapped in 2D or 3D, making it ideal for pollution source screening, industrial and environmental monitoring, and HAZMAT response.

    5 internal slots available for mounting sensing modules of your choice (see below).

    PM 1.0 & 2.5 & 10 Module (1 slot)
    Principle: Light Scattering
    Linear Range: 5~1,000 μg/m3
    Lowest Detection Limit: 5 μg/m3
    Display Resolution: 1 μg/m3
     

    O3 + NO2 Module (1 slot)
    Principle: Electrochemistry
    Linear Range: 0~11 ppm
    Lowest Detection Limit: 10 ppb
    Display Resolution: 1 ppb

    NO2 Module (1 slot)
    Principle: Electrochemistry
    Linear Range: 0~11 ppm
    Lowest Detection Limit: 10 ppb
    Display Resolution: 1 ppb

    CO Module (1 slot)
    Principle: Electrochemistry
    Linear Range: 0~11 ppm
    Lowest Detection Limit: 0.05 ppm
    Display Resolution: 0.005 ppm

    TVOC Module (1 slot)
    Principle: PID
    Linear Range: 0~50 ppm (Isobutylene)
    Lowest Detection Limit: 0.02 ppm
    Display Resolution: 0.01 ppm

    H2S Module (1 slot)
    Principle: Electrochemistry
    Linear Range: 0~90 ppm
    Lowest Detection Limit: 0.03 ppm
    Display Resolution: 0.01 ppm

    NH3 Module (1 slot)
    Principle: Electrochemistry
    Linear Range: 0~100 ppm
    Lowest Detection Limit: 1 ppm
    Display Resolution: 0.1 ppm

    Odor (OU, 1 slot)
    Principle: Electrochemistry
    Linear Range: 0~10 ppm
    Lowest Detection Limit: 0.1 ppm
    Display Resolution: 0.01 ppm

    TSP / PM 100 Module (5 slot)
    Principle: Light Scattering
    Linear Range: 30~3,000 μg/m3
    Lowest Detection Limit: 50 μg/m3
    Display Resolution: 1 μg/m3

    SO2 Module (1 slot)
    Principle: Electrochemistry
    Linear Range: 0~15 ppm
    Lowest Detection Limit: 0.03 ppm
    Display Resolution: 0.005 ppm

    HCHO Module (1 slot)
    Principle: Electrochemistry
    Linear Range: 0~100 ppm
    Lowest Detection Limit: 1 ppm
    Display Resolution: 0.1 ppm


    Recommended Configurations:
       Ambient air monitoring 1: PM 1.0 & 2.5 & 10 + O3 + NO2 + CO + TVOC
    Ambient air monitoring 2: PM 1.0 & 2.5 & 10 + O3 + NO2 + CO + SO2




    Sniffer4D Nano 2 Plus Multi-Gas mounted on a drone

    With DJI Matrice 4D / 4TD & Dock 3


    Real-Time Data Display & System Control via DJI Pilot App

    Real-Time Data Display & System Control via DJI Pilot App


    Frame 427319799.png

    With DJI Matrice 4E / 4T / 30 / 30T



    RECENTLY VIEWED PRODUCTS

    BACK TO TOP